Search results for "general [bl lacertae objects]"
showing 10 items of 27644 documents
Some approximation properties of a Durrmeyer variant ofq-Bernstein-Schurer operators
2016
Migration kinetics of ion-implanted beryllium in glassy carbon
2008
Abstract Migration kinetics of low-concentration implanted 7 Be in glassy carbon has been studied by the modified radiotracer technique at temperatures 1285 °C and 1340 °C. The annealed sample concentration profiles show two distinctive components: (i) Main profile broadening assigned to beryllium trapping in defects during annealing. (ii) Tail parts on both sides of the profile maximum related to faster migration. Of the latter the profile representing bulk diffusion lies on the region free of defect influence and is well described by concentration-independent diffusivity. The features of the concentration profile broadening towards the sample surface indicate partial Be trapping in defect…
Evolution of the microstructure of sputter deposited TaAlON thin films with increasing oxygen partial pressure
2021
Abstract Recently, quaternary oxynitrides of transition metals and aluminum have attracted increasing interest due to their tunable properties. Within the present work, a series of TaAl(O)N films was sputter deposited using constant nitrogen and varying oxygen partial pressures. The films were grown from single element Ta and Al targets. The deposition parameters were adjusted to obtain a Ta/Al atomic ratio of ~50/50 for the oxygen-free film and were held constant for the following depositions, with the exception of the increasing oxygen partial pressure and compensatory decreasing argon partial pressure. Elastic recoil detection analysis revealed oxygen contents of up to ~26 at.%, while th…
Insights into Intrinsic Defects and the Incorporation of Na and K in the Cu2ZnSnSe4 Thin-Film Solar Cell Material from Hybrid-Functional Calculations
2016
We have performed density functional theory calculations using the HSE06 hybrid functional to investigate the energetics, atomic, and electronic structure of intrinsic defects as well as Na and K impurities in the kesterite structure of the Cu2ZnSnSe4 (CZTSe) solar cell material. We found that both Na and K atoms prefer to be incorporated into this material as substitutional defects in the Cu sublattice. At this site highly stable (Na–Na), (K–K), and (Na–K) dumbbells can form. While Na interstitial defects are stable in CZTSe, the formation of K interstitial defects is unlikely. In general, the calculated formation energies for Na-related defects are always lower compared to their K-related…
Comparative Theoretical Analysis of BN Nanotubes Doped with Al, P, Ga, As, In, and Sb
2013
SUMMARY AND CONCLUDING REMARKS We have performed large-scale first-principles calculations ofthe electronic structure of (5,5) boron nitride nanotubescontaining the following substitutional impurity atoms: Al, P,Ga, As, In, and Sb. Calculations have been performed using thetwo methods: (i) linear combination of atomic orbitals(LCAO) with the atomic-centered Gaussian-type functions asa basis set and (ii) linearized augmented cylindrical wave(LACW) accompanied with the local density functional andmuffin-tin approximations for the electronic potential. In arelatively good qualitative agreement, both methods predict lowformation energies and, thus, relative stability of point defectsthat are assoc…
Analytical description of solid particles kinematics due to a fluid flow and application to the depiction of characteristic kinematics in cold sprayi…
2017
Abstract In several multiphase flow applications such as fluidization, thermal spraying, atomization manufacturing and so on, the Newton's law is widely enacted to formulate the particle/fluid kinematic interaction and then to compute particles kinematics. This paper provides analytical solutions of the Newton's law in its time-dependent formulation or simplified formulation, the latter being a reduction of the time dependent problem into a spatial description of the particle motion. It was found that the velocity solution is strictly similar in both cases so that the simplified formulation is viable. The W_ 1 branch of the Lambert's function yields the analytical particle residence time an…
Formation of dislocations and hardening of LiF under high-dose irradiation with 5–21 MeV 12C ions
2017
R. Zabels, I. Manika, J. Maniks, and R.Grants acknowledge the national project IMIS2, and A. Dauletbekova, M. Baizhumanov, and M. Zdorovets the Ministry of Education and Science of the Republic of Kazakhstan for the financial support.
Polarization and acoustic properties of barium-modified lead-free potassium–sodium niobate ceramics
2017
The publication costs of this article were covered by the Estonian Academy of Sciences and the University of Tartu.
Determination of Contact Potential Difference by the Kelvin Probe (Part II) 2. Measurement System by Involving the Composite Bucking Voltage
2016
Abstract The present research is devoted to creation of a new low-cost miniaturised measurement system for determination of potential difference in real time and with high measurement resolution. Furthermore, using the electrode of the reference probe, Kelvin method leads to both an indirect measurement of electronic work function or contact potential of the sample and measurement of a surface potential for insulator type samples. The bucking voltage in this system is composite and comprises a periodically variable component. The necessary steps for development of signal processing and tracking are described in detail.
Determination of Contact Potential Difference by the Kelvin Probe (Part I) I. Basic Principles of Measurements
2016
Abstract Determination of electric potential difference using the Kelvin probe, i.e. vibrating capacitor technique, is one of the most sensitive measuring procedures in surface physics. Periodic modulation of distance between electrodes leads to changes in capacitance, thereby causing current to flow through the external circuit. The procedure of contactless, non-destructive determination of contact potential difference between an electrically conductive vibrating reference electrode and an electrically conductive sample is based on precise control measurement of Kelvin current flowing through a capacitor. The present research is devoted to creation of a new low-cost miniaturised measuremen…